Watch your spacing of lateral restraint straps – a reminder of the regulations

Our surveyors are seeing more and more instances where lateral restraint straps to the head of gable walls are being applied at spacing greater than the maximum permitted 2m. Even if you are using pre-fabricated roof trusses, Part A of the Building Regulations and BS8103 remain clear that tensions straps should be no more than 2m apart.

Don’t rely on positioning lateral restraint straps at node points only

We see lateral restraint straps being placed at the node points of trusses, regardless of the spacing between these points. In cases where nodes are less than 2m apart, there is no problem. But in larger properties you should not rely on using node points alone for locating tension straps. The images below show an instance where the straps are too far apart, and not compliant with Part A of the Building Regulations and BS8103.

Gable Restraints more than 2m spacing

What the regulations say about lateral restraint straps

The regulations and BS8103 do not state that lateral restraint straps should be provided on the node points or longitudinal bracings only. They can be provided anywhere along the rafter line, with the strap hook turned over a full block and not partial or cut blocks.

Tension strap locationStrapping at gable wall

 

 

 

 

 

 

 

Every care was taken to ensure the information in this article was correct at the time of publication. For the most up to date LABC Warranty technical guidance please refer to your Risk Management Surveyor and the latest version of the LABC Warranty Technical Manual.

Was this post helpful? /